90-898305
1-24
TERMINATION RESISTOR PLACEMENT
NOTE: Termination resistors are designed to reduce noise and provide proper
DC voltage levels on the C.A.N. Bus circuit.
1. Each system must include exactly two (2) termination resistors.
2. Termination resistors must be located at the furthest ends of the main
C.A.N. Bus trunk.
3. The main C.A.N. Bus trunk may not exceed 36.6 m (120 ft.) in length
(measured along the cable). Main C.A.N. Bus Trunk is defined as the length of
cable located between termination resistors.
There are three (3) acceptable methods of adding termination resistors to the
system.
1. Junction box termination resistors.
2. Termination resistor inside the harness with a termination resistor at the
junction box.
3. Termination resistor inside the harness at both ends.
NOTE: Junction box termination resistors are designed to plug directly into
junction box ports.
Notes
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
_______________________
25
Vue de la page 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 178 179

Commentaires sur ces manuels

Pas de commentaire