172
CA453
Power Trim Does Not Operate
(Motor Doesnt Run)
Possible Cause Remedy
Blown fuse. Replace fuse.
Loose or dirty electrical
connections or damaged
wiring.
Check all associated electrical
connections and wires
(especially battery cables).
Clean and tighten faulty
connection. Repair or replace
wiring.
CA454
Power Trim Does Not Operate (Motor Runs But
Drive Unit Does Not Move)
Possible Cause Remedy
Trim pump oil level low. Fill pump with oil.
Drive unit binding in gimbal
ring.
Check for obstruction.